22,000 BTU Neola High-Wall

MODEL NUMBER: MEHS-22NiH2

Superior air conditioning for the entire home

  • Inverter ACs are more efficient to operate.
  • Easy installation with two way drainage.
  • Auto Restart - No need to power up after power failure.

Color: White

Contact your local dealer for price

Features

The Neola mini-split system is an air-conditining system designed to heat and cool the entire home. Inverter technology allows both the indoor and outdoor units to work in sync for efficient energy consumpation, and two-way draining ensures efficient operation at all times. The Auto-Restart feature means there's no need to power up after a power failure, and louver position memory makes sure your last louver setting is reintstated upon restart.

Inverter Technology

The inverter allows both the indoor and outdoor units to work in sync, ensuring that only the required energy is used for operation.

Two Way Draining

Install the drainage hose on the indoor unit from either the right or left side to suit your requirements.

Auto Restart Function

Retain previous mode and settings without the need to power up in the event of a power failure.

Louver Position Memory

The air outlet louver will automatcially move to the same position as was set the last time the unit was turned on.

Golden Fin Anti-Corrosive Coating

The anti-corrosive coating on the condenser can withstand weathering from outdoors, preventing bacteria growth and improving overall heat transfer efficency.

Specifications

General
Type Neola
AHRI # 7990689.0
Energy Star No
Performance
Nominal Cooling (BTU/H) 22000(6500-25000)
Nominal Heating (BTU/H) 22000(6500-26000)
Low Temp Heating @5°F (BTU/H) 13400.0
SEER (BTU / KW) 15.0
HSPF (BTU / KW) 8.2
HSPF5 /
EER (BTU / KW) 9.0
Cooling Operating Range (F ° Degrees) 32-122
Heating Operating Range (F ° Degrees) 5-86
Moisture Removal (Pints/Hour) 5.3
Electrical
Voltage / Phase / Frequency 208-230V~ 60Hz, 1Ph
Recommended In / Out Cable 16 AWG/4 (Standed) conductor
Power Use Rated (Cool / Heat) (KW) 2340 / 2150
Minimum Circuit Ampacity (Amps) 16.0
Running (Cool / Heat) (Amps) 10.6 / 9.7
Recommended Fuse Size (Amps) 25.0
Specification
Air Circulation Hi / Med / Low (CFM) 740/680/560
Indoor Noise Level: Hi/Med/Low (DBa) 49/45/39
Outdoor Noise Level Cooling (DBa) 60.0
Outdoor Noise Level Heating (DBa) 60.0
Air Direction Horizontal (Deg Angle) Automatic
Air Filter (Type) Washable
Connection (Type) Flare
Combined Minimum Length (Feet) 10.0
Combined Maximum Length (Feet) 98.0
Maximum Vertical Differential (Feet) 66.0
Connection Pipe Size Suction (Inches) 0.625
Connection Pipe Size Discharge (Inches) 0.375
Condensation Line Size (Inches) 0.625
Physical
Net Weight (LBS) 26.46
Height Condensing Unit (Inches) 27.56
Depth Condensing Unit (Inches) 12.6
Width Condensing Unit (Inches) 33.27
Height Evaporator (Inches) 12.4
Depth Evaporator (Inches) 8.58
Width Evaporator (Inches) 40.55
Refrigerant (Oz) R410A/56.44
Refrigerant piping - Liquid side/ Gas side mm(inch) Φ9.52/Φ15.9(3/8"/5/8")